How to Assemble a Camlock Fitting to a Hose: A Step-by-Step Guide

Share This Post

Most camlock leaks are assembly faults, not product faults. A hose shank pushed in too far, the wrong clamp, or an arm that was never fully closed will fail long before a correctly made joint. This is the sequence we recommend, and the checks that go with it.

Tools You Need

  • Hose cutter or angle grinder with a cutting disc
  • Tape measure and marker
  • Two hose clamps per connection (interlock or double-bolt)
  • Spanner or screwdriver for the clamp
  • Soap solution for the leak test
  • Optional: silicone grease for the cam arms, never for the gasket seat

Step 1: Confirm the Fitting Matches the Hose

The hose shank size refers to the hose inside diameter, not the outside. A 2″ shank goes into a 2″ ID hose. Check the type letter as well: a Type C has a coupler on the other end, a Type E has an adapter. The type chart is the quick reference.

Step 2: Cut the Hose Square

A square, clean cut is the difference between a joint that seals and one that weeps. Cut with a hose cutter or a fine abrasive disc, not a hacksaw, and inspect the cut face: any frayed reinforcement or ovality means cut again. Blow out the bore to remove swarf.

Step 3: Mark the Insertion Depth

Measure the shank length and mark it on the hose with a marker or a wrap of tape. The shank should go in until the mark meets the hose end — far enough to cover the barbs, not so far that the hose bottoms out against the shoulder and buckles.

Step 4: Insert the Shank

Warm the hose end in hot water if it is stiff, then push the shank in with a twisting motion until the mark is reached. Do not lubricate the shank: oil or grease lets the hose creep off under pressure. If it will not go in, the hose is undersized or the shank is the wrong size — do not force it with a hammer.

Step 5: Clamp It

Fit two clamps, positioned over the barbed section, with the band screws on opposite sides so the hose is compressed evenly. Tighten firmly but do not crush the hose wall. On suction lines, a clamp that is merely snug will draw air.

Step 6: Connect the Camlock Halves

  1. Check the gasket is seated in the coupler and is the right material.
  2. Push the adapter into the coupler until it seats against the gasket.
  3. Press both cam arms down until they click over centre. Both, not one.
  4. Tug the joint gently to confirm the arms are locked.

Step 7: Test Before Service

Run the line at working pressure with a soap solution on the joint. Bubbles mean a leak: release pressure, reseat the gasket, check the arms. On suction lines, watch for air ingress rather than outward leaks.

Common Assembly Mistakes

  • Clamping over the smooth part of the shank instead of the barbs.
  • One clamp where the line runs at pressure or vibrates.
  • Reusing a stretched or hardened hose end.
  • Forcing a BSP fitting into an NPT port because it “starts to go”.
  • Leaving the gasket out after cleaning.

When to Replace Rather Than Reassemble

If the hose end is cracked, the shank is corroded, or the cam groove is scored, reassembly will not fix it. Our inspection checklist sets out the wear limits, and hose menders can save a hose whose end has failed.