Two numbers decide whether a camlock fitting is safe on a line: the working pressure and the temperature. Both depend on more than the body material, which is why a simple “250 psi” claim on a datasheet is not enough to specify from.
What Changes the Rating
- Size — the larger the bore, the lower the rating. A 1″ fitting and a 6″ fitting in the same material are not interchangeable in pressure terms.
- Material — stainless and aluminum rate higher than brass, which rates higher than polypropylene.
- Gasket — the seal is the weak point at temperature; a soft gasket limits the joint long before the body does.
- Temperature — ratings fall as temperature rises, and the fall is steeper for plastics.
Working Pressure Guides
| Material | Working pressure guide | Temperature guide (gasket dependent) |
|---|---|---|
| 316 / 304 stainless steel | Up to 250 psi at small sizes | −40 to 200°C |
| Aluminum | 150–250 psi | −30 to 150°C |
| Brass | Around 150 psi | −20 to 120°C |
| Polypropylene | 50–100 psi | −20 to 70°C |
Treat these as starting points. The figure for your line is the one for your size, material, gasket and temperature together, and it should come from the manufacturer rather than from a general table.
Reading a Specification
When you see a pressure figure, check what it refers to:
- Is it a burst pressure or a working pressure? Working pressure is typically a quarter of burst.
- At what size? A figure quoted for 1″ does not apply to 4″.
- At what temperature? A room-temperature rating does not hold at 120°C.
- With which gasket? The gasket may be the limiting component.
Safety Margin
Do not run a camlock at its published maximum continuously. Leave headroom for pressure spikes, water hammer and temperature excursions, and remember that a worn gasket reduces the effective rating. If the line sees pulses from a piston pump or a fast-acting valve, treat the peak as the design pressure.
When Camlocks Are the Wrong Choice
Above roughly 250 psi, or where the fluid is at high temperature and high pressure together, a camlock is not the right family. Higher-rated couplings exist for those duties; forcing a camlock outside its envelope is how joints fail.