Most camlock ordering mistakes are not about the fitting. They are about the thread on the port it has to screw into. NPT, BSP, NPSH and NST look similar enough that the wrong one will start to engage, which is exactly why people force it — and then wonder why the joint weeps.
This guide explains what each thread standard is, where you will meet it, and how to identify the one on your pump, tank or hose before you order.
NPT: the North American pipe thread
NPT stands for National Pipe Taper. The thread has a 60° angle and tapers along its length, so the male and female threads interfere as they engage and seal against each other. A sealant — PTFE tape or thread compound — fills the spiral gap that remains.
You will find NPT on North American pumps, valves, tanks and instrumentation. It is the default on most US-built equipment and on fittings sold into the US market.
- 60° thread angle, tapered
- Seals on the threads, with sealant
- Common sizes: 1/8″ to 4″ NPT
BSP: the British and international pipe thread
BSP (British Standard Pipe) has a 55° angle and comes in two forms that behave differently:
- BSPP / G — parallel (straight) thread. It does not seal on the thread; it seals on a washer or an O-ring against a flat face.
- BSPT / R — tapered thread, which seals on the thread like NPT.
BSP is standard across the UK, Europe, Australia and much of Asia, and on equipment imported from those regions. A BSP fitting will often start to thread into an NPT port because the diameters are close — 1/2″ NPT and 1/2″ BSP differ by about one thread per inch — but the joint will not seal and the threads will be damaged.
NPSH and NST: hose threads, not pipe threads
These two are a different family. They are hose threads, used on fire hoses, water hose and pump connections, and they are defined by hose standards rather than pipe standards.
- NST — National Standard Thread, the common North American fire-hose thread.
- NPSH — National Pipe Straight Hose, a straight hose thread used on water hose and some pump and hydrant connections.
They look similar, they are both used on hose, and they are not interchangeable in every combination. If you are replacing a hose end on a fire main or a water pump, identify the existing thread with a gauge rather than assuming.
How to tell them apart
| Standard | Angle | Taper | Seals on |
|---|---|---|---|
| NPT | 60° | Tapered | Threads + sealant |
| BSPT (R) | 55° | Tapered | Threads + sealant |
| BSPP (G) | 55° | Parallel | Washer or O-ring face |
| NPSH | Hose standard | Straight | Hose gasket |
| NST | Hose standard | Hose thread | Hose gasket |
Three checks that settle it
- Count the threads per inch with a thread pitch gauge. NPT and BSP differ at every size, and the difference is measurable on the first inch.
- Check the angle with a thread profile gauge: 60° for NPT, 55° for BSP. At arm’s length they look the same; under a gauge they do not.
- Check the port, not the fitting. Read the equipment nameplate or manual. If the pump was built in Europe, assume BSP until proven otherwise.
The mistakes that cost the most
- Forcing BSP into NPT. The first two turns feel normal, then the thread deforms. Both the port and the fitting are now scrap.
- Using tape on BSPP. A parallel thread seals on its face; tape on the thread does nothing and can crack the port if over-tightened.
- Assuming all hose threads are NST. NPSH and NST are different standards; a mismatch leaks at the gasket face.
- Mixing standards on one skid. If half the ports are NPT and half BSP, someone will eventually connect the wrong pair. Standardise adapters per port.
What we supply
Camlock fittings are cut NPT or BSP to order across the range, from 1/2″ to 6″. Pin lug couplings can be supplied with NPSH, NST or BSP threads for hose and pump connections. If you are not sure which one your port uses, send a photo of the port with a ruler across the thread and we will confirm.
For the rest of the fitting — type letter, size, material and gasket — the camlock fitting types guide covers the letters, and the type chart is the one-page version.
FAQ
Can I use an NPT fitting in a BSP port?
No. They will start to engage, which is the trap, but the thread angles and pitches differ. The joint will leak and the threads will be damaged. Use the correct standard or a documented adapter.
Is BSP the same as BSPT?
No. BSPT is the tapered form, which seals on the thread. BSPP is the parallel form, which seals on a washer or O-ring face. The two are not interchangeable in a sealing joint.
How do I know if my pump is NPT or BSP?
Check the nameplate, manual or original invoice. If none is available, measure the thread pitch and angle with a gauge. Where the equipment was manufactured is a strong hint: North American equipment is usually NPT, European and Asian equipment is usually BSP.
Do camlock fittings come with thread sealant pre-applied?
No. Tapered threads need tape or compound at installation; parallel threads seal on their face and should not be taped. Our assembly guide covers the sequence.
If you send us the port size, a photo and the equipment origin, we will confirm the thread standard and quote the matching aluminum or stainless steel camlock fitting.